DSP
PAR
%PW
DEV
MAN
OP1
AL1
AL2
.40
1.95
3.80
(96.5)
(10.2)
3.60
(91.4)
5.29
5.41
1.75
(44.4)
(134.4)
(137.4)
(49.5)
1.77
(45 )
3.62
(92 )
+.02
-.00
+.6
-.0
+.03
-.00
+.8
-.0
100 MSEC SAMPLING PERIOD WITH 0.15% ACCURACY
ON DEMAND AUTO-TUNING OF PID CONTROL SETTINGS
DUAL LED DISPLAYS FOR SIMULTANEOUS INDICATION OF
PROCESS VALUE AND SETPOINT OR SECOND ANALOG INPUT
ACCEPTS EITHER 0 to 10 VDC OR 0 to 20 mA DC INPUTS
SELF-DIAGNOSTICS
FULL PID CONTROL WITH REDUCED OVERSHOOT
OPTIONAL RS485 SERIAL COMMUNICATIONS INTERFACE
OPTIONAL DUAL ALARM OUTPUTS (USES OUTPUT MODULES)
OPTIONAL SECONDARY OUTPUT (USES OUTPUT MODULE)
OPTIONAL LINEAR 4 to 20 mA OR 0 to 10 VDC OUTPUT FOR
CONTROL OR PROCESS VALUE RE-TRANSMISSION
OPTIONAL MOTORIZED VALVE POSITION CONTROL AND
VALVE FAIL ALARM
OPTIONAL SECOND ANALOG INPUT FOR REMOTE SETPOINT
AND CASCADE CONTROL
OPTIONAL TYPE 4X/IP65 SEALED FRONT BEZEL
STATUS INDICATORS FOR OUTPUTS AND CONTROL MODES
PROGRAMMABLE USER INPUT (DIGITAL) FOR ADDED
FLEXIBILITY
MANUAL/AUTOMATIC AND LOCAL/REMOTE SETPOINT
CONTROL MODES
SETPOINT RAMPING FOR PROCESS STARTUP
PARAMETER SECURITY VIA PROGRAMMABLE LOCKOUTS
FIELD REPLACEABLE AND INTERCHANGEABLE OUTPUT
MODULES (Relay, Logic/SSR Drive and Triac)
DESCRIPTION
The PCU Controller accepts either 0 to 10 VDC or a 0 to 20 mA DC input
signal, precisely scales the process signal according to programmable scaling
points, and provides an accurate output control signal (time proportional, linear,
or valve position) to maintain a process at the desired control point. A
comprehensive set of easy to use program instructions allows the controller to
solve various applications.
The controller can operate in the PID control mode for both the main output
and optional secondary output, with on-demand auto-tune, that establishes the
tuning constants. The PID tuning constants may be fine-tuned by the operator
at any time and then locked-out from further modification. The controller
employs a unique overshoot suppression feature, which allows the quickest
response without excessive overshoot. The unit can be transferred to operate in
the manual mode, providing the operator with direct control of the output. The
controller may also be programmed to operate in the ON/OFF control mode
with adjustable hysteresis.
Dual 4-digit displays allow viewing of the process value and setpoint
simultaneously. Front panel indicators inform the operator of the controller and
output status. Replaceable and interchangeable output modules (Relay, Logic/
SSR Drive, or Triac) can be installed for the main control output, alarm
output(s) and secondary output.
MODEL PCU - PROCESS CONTROL UNIT
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 5.5" (140) H x 2.1" (53.4) W.
Bulletin No. PCU-F
Drawing No. LP0338
Released 08/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
C
US LISTED
U
L
R
51EB
IND. CONT. EQ.
PANEL CUT-OUT
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - US LISTED

1DSPPAR%PWDEVMANOP1AL1AL2.401.953.80(96.5)(10.2)3.60(91.4)5.295.411.75(44.4)(134.4)(137.4)(49.5)1.77(45 )3.62(92 )+.02-.00+.6-.0+.03-.00+.8-.0

Strona 2 - SPECIFICATIONS

2OPTIONSOptional dual alarms can be configured to activate according to a variety of actions (Absolute HI or LO, Deviation HI or LO, Band IN or OUT an

Strona 3 - FRONT PANEL FEATURES

3SPECIFICATIONS (Cont’d)8. SECONDARY OUTPUT (Optional):Control: PID or ON/OFFOutput: Time proportioning or linear DCHardware: Plug-in, replaceable out

Strona 4 - MOTORIZED VALVE POSITIONER

4HARDWARE FEATURESThe fast 100 msec input sampling rate provides quick controller response to a process disturbance, thus providing excellent process

Strona 5 - INTERNAL CASCADE

5INTERNAL CASCADECascade control allows the process to be divided into two control loops: the primary control loop and the secondary control loop. The

Strona 6 - CONTROLLER PROGRAMMING

6CONTROLLER PROGRAMMINGThe PCU has been designed to reduce the operator interaction with the controller while still maintaining a high degree of contr

Strona 7 - APPLICATION

7PROTECTED PARAMETERS MODE *The protected parameters mode is enabled when program disable is active. This mode prevents access to the configuration m

Strona 8 - ORDERING INFORMATION

ORDERING INFORMATIONMODELS WITHOUT SECOND INPUT OPTIONSSECOND ANALOG INPUT MODELS (RSP)MOTORIZED VALVE POSITIONER MODELS (MVP)ACCESSORIESNote: Output